The Master Logg ML-260 data logger with universal inputs is the perfect solutions for industrial and automation applications.
Features:
- Universal Analog Inputs
- High Performance
- Simultaneous Measurement Of Channels
- High Accuracy
- Gain Selectable on Channels
- Data Record on Micro SD
- Programmable High and Low Alarms
- Real Time Data View in Software
- Alarm Display on LCD
The Master Logg ML-260 data logger
with universal inputs is the perfect solutions for industrial and automation
applications.
The Master Logg analog inputs are configurable to measure voltage, current, Pt100 & Thermocouples, also digital channels can be used to detect pulse changes and frequency measurements.
Master Logg software is used for data
read out, device configuration, reading real time values and live charting.
Additional eight channel Relay Control
Unit can be ordered to control peripherals in case of alarm on any input
channels.
Low noise internal amplifier allows
users to select gains for each input channels from 1 ~ 128.
Measured signal values automatically convert
to engineering units as user configuration.
General Parameters:
Channel Numbers | 8 Analog, 2 Digital |
Analog Inputs | 0 ~ 25mA 0 ~ 5VDC PT100 Thermocouple |
Digital Inputs | Pulse Max 20VDC Frequency up to 10Khz |
Measure Time | 4 HZ |
Power | 12 ~ 35 VDC |
Memory | External micro SD support up to 32GB |
Logging Time Interval | 0.25 seconds ~ 24 hours (configured by software) |
Interface | USB-B Port 1x RS232/RS485 |
Working Temperature | -30 ~ 80°C Not for use in condensing conditions |
Dimensions | 157.4x103x57.6 mm |
Voltage Characteristic
Input Ranges Single Ended: 0 ~ 5 VDC
unipolar/bipolar:
± 2.5VDC/Gain
For example Gain=128
Input Rage= ±19.53mVDC
Gain Select 1~128
Noise RMS 5.1 μV @ Gain=1
2.5 μV @ Gain=2
1.2 μV @ Gain=4
0.7 μV @ Gain=8~128
Resolution 0.1 mv @ 0 ~ 5 VDC
10 μV @ ± 2.5V
5 μV @ ± 1.25V
1 μV @ ± 300 mV
Accuracy 5 mV @ 0 ~ 5 VDC
100 μV @ ± 2.5V
50 μV @ ± 1.25V
10 μV @ ± 300 mV
Current Characteristic
Measure Range 0 ~ 25mA
Resolution 0.1 μA
Accuracy 3 μA
Input Impedance 100 Ω
RTD Characteristic
Probe Type PT100
2-3-4 wire connection
Resolution 0.01 °C
Accuracy 0.5°C
Thermocouple Measuring Characteristic
Probe Type J,R,S,B,N,K,E,T
Resolution 0.1 °C
Accuracy 0.5°C @ J,N,K,E,T
1°C @ R,S,B
ML-260 MASTER LOGGER
Product No. | Details |
---|---|
ML-260.10.1 | Master Logg Universal Input Data Logger with RS232 Interface |
ML-260.10.2 | Master Logg Universal Input Data Logger with RS485 Interface |
MLC-08 | 8 channel Relay Controller for Master Logg Connects using RS485 Interface |