TL-310 particulate matter data loggers with laser-based sensor detects, counts particles and record values. The detection concentration range is 0 µg/m3 to 1,000 µg/m3, Enables the ability to more accurately and cost competitively monitor or control environmental particulate. Faster response time of <6 s allows the TL310 Series to respond to environmental conditions in real-time
Features:
- Long term stability
Laser-based sensor
- 10 years of sensor life
- Response time:<6s
- Optional WIFI Support (TCP/IOT Device)
- Optional GSM Support (SMS/GPRS)
- Optional ISO-17025 accredited calibration certificate.
- High Accuracy
- Battery Operation
- Internal Memory
- Programmable High and Low Alarms
- Real Time Data View in Software
- Alarm Display on LCD

TL-310 particulate matter data loggers with laser-based sensor detects, counts particles and record values. The detection concentration range is 0 µg/m3 to 1,000 µg/m3, Enables the ability to more accurately and cost competitively monitor or control environmental particulate. Faster response time of <6 s allows the TL310 Series to respond to environmental conditions in real-time.
Stored values can be transferred to pc via USB port and Daloco software. Device configuration, reading real values and live charting can be done by easy to use Daloco software.
Optional GSM functionality Supports GPRS connection and SMS Short messages can be send to user during alarm and also on predefined intervals, also Using GPRS connection data can be upload to the Teknologg cloud servers.
Optional WIFI functionality Supports TCP/IP connection for monitoring on local networks and also can be setup as IOT device to use Teknologg cloud servers for remote monitoring.
| PM | Characteristics |
|---|---|
| Mass concentration | 0 ~ 1000 μg/m3 |
| Mass concentration size range | PM1.0/ PM2.5/ PM4/ PM10 |
| Mass concentration precision for PM2.5 | For 0 to 100 μg/m3 : ±15µg/m3 For 100 to 1000 μg/m3: ±15 % m.v |
| Mass concentration precision for PM1,PM4, PM10 | For 0 to 100 μg/m3: ±25 μg/m3 For 100 to 1000 μg/m3: ±25 % m.v |
| Operating Conditions | Humidity: 0 %RH to 95 %RH Temperature: -20°C to 70°C non-condensing |
| Response Time | <6 s |
| Laser Class | Laser Class 1: IEC/EN 60825-1: 650 nm |
General Parameters:
| Measure Time | 1 seconds ~ 24 hours (configured by software) |
| Battery | Lithium-Polymer Rechargeable Battery |
| Memory | Internal:70000 Records |
| Logging Time Interval | 1 seconds ~ 24 hours (configured by software) |
| Interface | USB Type-C |