TL-180 data logger with built in sensors are used for measuring, displaying and recording of Formaldehyde, temperature, humidity.
Features:
- Long term stability
 - Electrochemical based internal sensor
 - Low cross-sensitivity to ethanol
 - Optional ISO-17025 accredited calibration certificate.
 - High Accuracy
 - Capability to Calibration up to 20 Reference points
 - Battery Operation
 - Internal Memory with External Micro SD support
 - Programmable High and Low Alarms
 - Real Time Data View in Software
 - Alarm Display on LCD
 



TL-180 multi parameter data loggers with built in sensors are used for measuring, displaying and storing of formaldehyde levels, humidity and Temperature, Humidity & data.
TL-180 measures formaldehyde based on electrochemical sensing technology optimized for lowest false alarm rates internal sensor has a low cross-sensitivity to ethanol and is optimized to operate in the low parts-per-billion (ppb) range to accurately detect low HCHO concentrations around the WHO reference value for indoor exposure. Internal Temperature and humidity compensation ensures reliable performance in changing indoor environments.
Stored values can be transferred to pc via USB port and Daloco software. Device configuration, reading real values and live charting can be done by easy to use Daloco software.
This device features calibration capability which can be tested and calibrated up to 20 reference points in calibration laboratories.
| formaldehyde | Characteristics | 
|---|---|
| Probe Type | Internal Electrochemical Sensor | 
| Standard Measuring range | 0 ~ 1000 ppb | 
| Maximum Measuring range | 5000 ppb  Value at which the sensor saturates  | 
| Accuracy | ±20 ppb or ±20% of measured value, whichever is larger | 
| Repeatability | ±5 ppb or ±5% of measured value, whichever is larger | 
| Response Time | <2 min | 
| Resolution | 1 ppb | 
| Long-term drift | <5 ppb or <5% of measured value, whichever is larger | 
	 
Temperature Characteristic 
	 
Probe Type Internal Digital sensor 
	 
Measuring range  -20 ~ 50 °C      
Not for use in condensing conditions
	 
Accuracy ±0.2 °C typical 
	 
Repeatability  ±0.1 °C 
	 
Resolution 0.1 °C  
	 
Long-term drift  <0.03 °C/yr. 
	 
Humidity Characteristic 
	 
Probe Type Internal  sensor 
	 
Measuring range  0 ~ 100% 
Not for use in condensing conditions
	 
Accuracy  typ. ±2.5% R.H  
	 
Repeatability  0.2 % R.H  
	 
Resolution  0.1 % R.H 
	 
Long-term drift : <0.25 %RH/yr. 
WIFI Characteristics
	 
Frequency 2.4GHz EEE802.11b/g/n 
	 
Output Power +20dbm for 11b mode 
	 
Receiver Sensitivity -94 dBm 
	 
WIFI Modes Station/SoftAP 
General Parameters:
| Measure Time | 10 seconds ~ 24 hours (configured by software) | 
| Battery | 1*3.6v (14500) Lithium-ion Rechargeable Battery | 
| Memory | Internal:70000 Temperature & Co2 Records External micro SD support up to 32GB  | 
| Logging Time Interval | 10 seconds ~ 24 hours (configured by software) | 
| Interface | Mini USB-B Port | 
| Dimensions | 110x76x27mm | 